Advanced Reactivity Measurement Facility I (ARMF-I) was a research reactor which was located at the Argonne National Laboratory, a United States Department of Energy national laboratory, facility located in the high desert of southeastern Idaho between Idaho Falls, Idaho and Arco, Idaho. ARMF-I was nearly identical to ARMF-II.

History

[edit]

The ARMF-I, a reactor located in a small pool in a building east of the MTR in the Test Reactor Area, was used to determine the nuclear characteristics of reactor fuels and other materials subject to testing in the MTR. Together with the MTR, the reactor helped improve the performance, reliability, and quality of reactor core components. Until the next generation reactor, the ARMF-II, this was considered the most sensitive device for reactivity determinations then in existence.[1]

The Advanced Reactivity Measurement Facilities, ARMF-I and ARMF-II, were nearly identical critical facilities and were used almost exclusively for measuring reactor physics parameters, such as reactor-spectrum cross sections and resonance integral cross sections. They were designed to (a) have large statistical weights for fuels and poisons, (b) be mechanically stable enough to produce reproducible reactivity measurements, and (c) have sensitive instrumentation capable of measuring very small reactivities.[2]

ARMF-I operated from October 10, 1960, until 1974.[1]

Design

[edit]

ARMF-I and ARMF-II were near identical pool reactors.[1] ARMF-I and ARMF-II were housed in a 40-foot by 60-foot cinder block building located just east of the MTR canal tunnel; the building was designed from the initial concept for two reactors. These facilities were swimming-pool-type reactors having light-water moderated cores made up of plate-type fuel elements containing high enriched uranium at 93% U-235. The facilities were located at the National Reactor Testing Station near the Materials Testing Reactor (MTR). Being located near the MTR permitted measurements on short-lived fission products and transmuted isotopes. By use of the capsule 'transfer tube' connecting the MTR and ARMF canals, a capsule could be transferred from the MTR hydraulic rabbit to the ARMF and prepared for reactivity measurements in 15 minutes.[2]

Bibliography

[edit]

See also

[edit]

References

[edit]

Citations

  1. ^ a b c https://factsheets.inl.gov/FactSheets/PtP-appendices.pdf Archived 2020-09-27 at the Wayback Machine Stacy, Susan M. “Proving the Principle – Appendix B: Fifty Years of Reactors at the INEEL”. 2000.
  2. ^ a b https://www.osti.gov/servlets/purl/4330818 Burdick, E.E., et al. "The Advanced Reactivity Measurement Facilities". IDO-17005. October 1964. Phillips Petroleum Company on behalf of the US Atomic Energy Commission.