Lockhart–Martinelli parameter
Appearance
The Lockhart–Martinelli parameter () is a dimensionless number used in internal two-phase flow calculations.[1] It expresses the liquid fraction of a flowing fluid. Its main application is in two-phase pressure drop and boiling/condensing heat transfer calculations.
It is defined as:
where
- is the liquid phase mass flowrate;
- is the gas phase mass flowrate;
- is the gas density;
- is the liquid density.
See also
[edit]References
[edit]- ^ Lockhart, R.W., Martinelli, R.C.; Chem. Eng. Prog., Vol. 45. 1949, pp. 39–48