Jump to content

Thermography

From Wikipedia, the free encyclopedia
(Redirected from IR detector)
Thermogram of a traditional building in the background and a "passive house" in the foreground

Infrared thermography (IRT), thermal video or thermal imaging, is a process where a thermal camera captures and creates an image of an object by using infrared radiation emitted from the object in a process, which are examples of infrared imaging science. Thermographic cameras usually detect radiation in the long-infrared range of the electromagnetic spectrum (roughly 9,000–14,000 nanometers or 9–14 μm) and produce images of that radiation, called thermograms. Since infrared radiation is emitted by all objects with a temperature above absolute zero according to the black body radiation law, thermography makes it possible to see one's environment with or without visible illumination. The amount of radiation emitted by an object increases with temperature; therefore, thermography allows one to see variations in temperature. When viewed through a thermal imaging camera, warm objects stand out well against cooler backgrounds; humans and other warm-blooded animals become easily visible against the environment, day or night. As a result, thermography is particularly useful to the military and other users of surveillance cameras.

Thermogram of a cat

Some physiological changes in human beings and other warm-blooded animals can also be monitored with thermal imaging during clinical diagnostics. Thermography is used in allergy detection and veterinary medicine. Some alternative medicine practitioners promote its use for breast screening, despite the FDA warning that "those who opt for this method instead of mammography may miss the chance to detect cancer at its earliest stage".[1] Government and airport personnel used thermography to detect suspected swine flu cases during the 2009 pandemic.[2]

Thermal imaging camera and screen. Thermal imaging can detect elevated body temperature, one of the signs of the virus H1N1 (swine influenza).

Thermography has a long history, although its use has increased dramatically with the commercial and industrial applications of the past fifty years. Firefighters use thermography to see through smoke, to find persons, and to localize the base of a fire. Maintenance technicians use thermography to locate overheating joints and sections of power lines, which are a sign of impending failure. Building construction technicians can see thermal signatures that indicate heat leaks in faulty thermal insulation and can use the results to improve the efficiency of heating and air-conditioning units.

The appearance and operation of a modern thermographic camera is often similar to a camcorder. Often the live thermogram reveals temperature variations so clearly that a photograph is not necessary for analysis. A recording module is therefore not always built-in.

Specialized thermal imaging cameras use focal plane arrays (FPAs) that respond to longer wavelengths (mid- and long-wavelength infrared). The most common types are InSb, InGaAs, HgCdTe and QWIP FPA. The newest technologies use low-cost, uncooled microbolometers as FPA sensors. Their resolution is considerably lower than that of optical cameras, mostly 160x120 or 320x240 pixels, up to 1280 x 1024[3] for the most expensive models. Thermal imaging cameras are much more expensive than their visible-spectrum counterparts, and higher-end models are often export-restricted due to the military uses for this technology. Older bolometers or more sensitive models such as InSb require cryogenic cooling, usually by a miniature Stirling cycle refrigerator or liquid nitrogen.

Thermal energy

[edit]
A comparison of a thermal image (top) and an ordinary photograph (bottom). The plastic bag is mostly transparent to long-wavelength infrared, but the man's glasses are opaque.
This thermogram shows excessive heating on a terminal in an industrial electrical fuse block.
A thermal image showing temperature variation in a hot air balloon

Thermal images, or thermograms, are actually visual displays of the amount of infrared energy emitted, transmitted, and reflected by an object. Because there are multiple sources of the infrared energy, it is difficult to get an accurate temperature of an object using this method. A thermal imaging camera is capable of performing algorithms to interpret that data and build an image. Although the image shows the viewer an approximation of the temperature at which the object is operating, the camera is actually using multiple sources of data based on the areas surrounding the object to determine that value rather than detecting the actual temperature.[4]

This phenomenon may become clearer upon consideration of the formula:

Incident Radiant Power = Emitted Radiant Power + Transmitted Radiant Power + Reflected Radiant Power;

where incident radiant power is the radiant power profile when viewed through a thermal imaging camera. Emitted radiant power is generally what is intended to be measured; transmitted radiant power is the radiant power that passes through the subject from a remote thermal source, and; reflected radiant power is the amount of radiant power that reflects off the surface of the object from a remote thermal source.

This phenomenon occurs everywhere, all the time. It is a process known as radiant heat exchange, since radiant power × time equals radiant energy. However, in the case of infrared thermography, the above equation is used to describe the radiant power within the spectral wavelength passband of the thermal imaging camera in use. The radiant heat exchange requirements described in the equation apply equally at every wavelength in the electromagnetic spectrum.

If the object is radiating at a higher temperature than its surroundings, then power transfer will be taking place and power will be radiating from warm to cold following the principle stated in the second law of thermodynamics. So if there is a cool area in the thermogram, that object will be absorbing the radiation emitted by the warm object.

The ability of objects to emit is called emissivity, to absorb radiation is called absorptivity. Under outdoor environments, convective cooling from wind may also need to be considered when trying to get an accurate temperature reading.

The thermal imaging camera would next employ a series of mathematical algorithms. Since the camera is only able to see the electromagnetic radiation that is impossible to detect with the human eye, it will build a picture in the viewer and record a visible picture, usually in a JPG format.

In order to perform the role of non-contact temperature recorder, the camera will change the temperature of the object being viewed with its emissivity setting.

Other algorithms can be used to affect the measurement, including the transmission ability of the transmitting medium (usually air) and the temperature of that transmitting medium. All these settings will affect the ultimate output for the temperature of the object being viewed.

This functionality makes the thermal imaging camera an excellent tool for the maintenance of electrical and mechanical systems in industry and commerce. By using the proper camera settings and by being careful when capturing the image, electrical systems can be scanned and problems can be found. Faults with steam traps in steam heating systems are easy to locate.

In the energy savings area, the thermal imaging camera can do more. Because it can see the effective radiation temperature of an object as well as what that object is radiating towards, it can help locate sources of thermal leaks and overheated regions as well.

Emissivity

[edit]

Emissivity is a term that is often misunderstood and misused. It represents a material's ability to emit thermal radiation and is an optical property of matter.

Each material has a different emissivity, which may vary by temperature and infrared wavelength.[5] For example, clean metal surfaces have emissivity that decreases at longer wavelengths; many dielectric materials, such as quartz (SiO2), sapphire (Al2O3), calcium fluoride (CaF2), etc. have emissivity that increases at longer wavelength; simple oxides, such as iron oxide (Fe2O3) display relatively flat emissivity in the infrared spectrum.

A material's emissivity can range from a theoretical 0.00 (completely not-emitting) to an equally theoretical 1.00 (completely emitting). An example of a substance with low emissivity would be silver, with an emissivity coefficient of .02. An example of a substance with high emissivity would be asphalt, with an emissivity coefficient of .98.

A black body is a theoretical object with an emissivity of 1 that radiates thermal radiation characteristic of its contact temperature. That is, if the contact temperature of a thermally uniform black body radiator were 50 °C (122 °F), the black body would emit thermal radiation characteristic of 50 °C (122 °F).

Thermogram of a snake held by a human

An ordinary object emits less infrared radiation than a theoretical black body. The fraction of its actual emission to the theoretical emission (of the black body) is its emissivity (or emissivity coefficient).

In order to make a temperature measurement of an object using an infrared imager, it is necessary to estimate or determine the object's emissivity. For quick work, a thermographer may refer to an emissivity table for a given type of object, and enter that value into the imager. The imager would then calculate the object's contact temperature based on the value entered from the table and the object's emission of infrared radiation as detected by the imager.

In order to get a more accurate temperature measurement, a thermographer may apply a standard material of known, high emissivity to the surface of the object. The standard material might be as complex as industrial emissivity spray produced specifically for the purpose, or as simple as standard black insulation tape, with an emissivity of about 0.97. The object's known temperature can then be measured using the standard emissivity. If desired, the object's actual emissivity (on a part of the object that is not covered by the standard material) can then be determined by adjusting the imager's setting to the known temperature. There are situations, however, when such an emissivity test is not possible due to dangerous or inaccessible conditions. In these situations, the thermographer must rely on tables.

Cameras

[edit]
Image of a Pomeranian taken in mid-infrared ("thermal") light (false-color)

A thermographic camera (also called an infrared camera or thermal imaging camera, thermal camera or thermal imager) is a device that creates an image using infrared (IR) radiation, similar to a normal camera that forms an image using visible light. Instead of the 400–700 nanometre (nm) range of the visible light camera, infrared cameras are sensitive to wavelengths from about 1,000 nm (1 micrometre or μm) to about 14,000 nm (14 μm). The practice of capturing and analyzing the data they provide is called thermography.

Types

[edit]

Thermographic cameras can be broadly divided into two types: those with cooled infrared image detectors and those with uncooled detectors.

Cooled infrared detectors

[edit]
A thermographic image of several lizards
Thermal imaging camera & screen, in an airport terminal in Greece. Thermal imaging can detect fever, one of the signs of infection.

Cooled detectors are typically contained in a vacuum-sealed case or Dewar and cryogenically cooled. The cooling is necessary for the operation of the semiconductor materials used. Typical operating temperatures range from 4 K (−269 °C) to just below room temperature, depending on the detector technology. Most modern cooled detectors operate in the 60 Kelvin (K) to 100 K range (-213 to -173 °C), depending on type and performance level.[6]

Without cooling, these sensors (which detect and convert light in much the same way as common digital cameras, but are made of different materials) would be 'blinded' or flooded by their own radiation. The drawbacks of cooled infrared cameras are that they are expensive both to produce and to run. Cooling is both energy-intensive and time-consuming.

The camera may need several minutes to cool down before it can begin working. The most commonly used cooling systems are peltier coolers which, although inefficient and limited in cooling capacity, are relatively simple and compact. To obtain better image quality or for imaging low temperature objects Stirling engine cryocoolers are needed. Although the cooling apparatus may be comparatively bulky and expensive, cooled infrared cameras provide greatly superior image quality compared to uncooled ones, particularly of objects near or below room temperature. Additionally, the greater sensitivity of cooled cameras also allow the use of higher F-number lenses, making high performance long focal length lenses both smaller and cheaper for cooled detectors.

An alternative to Stirling engine coolers is to use gases bottled at high pressure, nitrogen being a common choice. The pressurised gas is expanded via a micro-sized orifice and passed over a miniature heat exchanger resulting in regenerative cooling via the Joule–Thomson effect. For such systems the supply of pressurized gas is a logistical concern for field use.

Materials used for cooled infrared detection include photodetectors based on a wide range of narrow gap semiconductors including indium antimonide (3-5 μm), indium arsenide, mercury cadmium telluride (MCT) (1-2 μm, 3-5 μm, 8-12 μm), lead sulfide, and lead selenide.

Infrared photodetectors can be created with structures of high bandgap semiconductors such as in quantum well infrared photodetectors.

A number of superconducting and non-superconducting cooled bolometer technologies exist.

In principle, superconducting tunneling junction devices could be used as infrared sensors because of their very narrow gap. Small arrays have been demonstrated. They have not been broadly adopted for use because their high sensitivity requires careful shielding from the background radiation.

Superconducting detectors offer extreme sensitivity, with some able to register individual photons. For example, ESA's Superconducting camera (SCAM). However, they are not in regular use outside of scientific research.

Uncooled infrared detectors

[edit]

Uncooled thermal cameras use a sensor operating at ambient temperature, or a sensor stabilized at a temperature close to ambient using small temperature control elements. Modern uncooled detectors all use sensors that work by the change of resistance, voltage or current when heated by infrared radiation. These changes are then measured and compared to the values at the operating temperature of the sensor.

Uncooled infrared sensors can be stabilized to an operating temperature to reduce image noise, but they are not cooled to low temperatures and do not require bulky, expensive, energy consuming cryogenic coolers. This makes infrared cameras smaller and less costly. However, their resolution and image quality tend to be lower than cooled detectors. This is due to differences in their fabrication processes, limited by currently available technology. An uncooled thermal camera also needs to deal with its own heat signature.

Uncooled detectors are mostly based on pyroelectric and ferroelectric materials or microbolometer technology.[7] The material are used to form pixels with highly temperature-dependent properties, which are thermally insulated from the environment and read electronically.

Thermal image of steam locomotive

Ferroelectric detectors operate close to phase transition temperature of the sensor material; the pixel temperature is read as the highly temperature-dependent polarization charge. The achieved NETD of ferroelectric detectors with f/1 optics and 320x240 sensors is 70-80 mK. A possible sensor assembly consists of barium strontium titanate bump-bonded by polyimide thermally insulated connection.

Silicon microbolometers can reach NETD down to 20 mK. They consist of a layer of amorphous silicon, or a thin film vanadium(V) oxide sensing element suspended on silicon nitride bridge above the silicon-based scanning electronics. The electric resistance of the sensing element is measured once per frame.

Current improvements of uncooled focal plane arrays (UFPA) are focused primarily on higher sensitivity and pixel density. In 2013 DARPA announced a five-micron LWIR camera that uses a 1280 x 720 focal plane array (FPA).[8] Some of the materials used for the sensor arrays are amorphous silicon (a-Si), vanadium(V) oxide (VOx),[9] lanthanum barium manganite (LBMO), lead zirconate titanate (PZT), lanthanum doped lead zirconate titanate (PLZT), lead scandium tantalate (PST), lead lanthanum titanate (PLT), lead titanate (PT), lead zinc niobate (PZN), lead strontium titanate (PSrT), barium strontium titanate (BST), barium titanate (BT), antimony sulfoiodide (SbSI), and polyvinylidene difluoride (PVDF).

Specifications

[edit]

Some specification parameters of an infrared camera system are number of pixels, frame rate, responsivity, noise-equivalent power, noise-equivalent temperature difference (NETD), spectral band, distance-to-spot ratio (D:S), minimum focus distance, sensor lifetime, minimum resolvable temperature difference (MRTD), field of view, dynamic range, input power, and mass and volume.

Difference from infrared film

[edit]

IR film is sensitive to infrared (IR) radiation in the 250 to 500 °C (482 to 932 °F) range, while the range of thermography is approximately −50 to 2,000 °C (−58 to 3,632 °F). So, for an IR film to work thermographically, the measured object must be over 250 °C (482 °F) or be reflecting infrared radiation from something that is at least that hot.

Night vision infrared devices image in the near-infrared, just beyond the visual spectrum, and can see emitted or reflected near-infrared in complete visual darkness. However, again, these are not usually used for thermography due to the high temperature requirements, but are instead used with active near-IR sources.

Starlight-type night vision devices generally only magnify ambient light.

Passive vs. active thermography

[edit]

All objects above the absolute zero temperature (0 K) emit infrared radiation. Hence, an excellent way to measure thermal variations is to use an infrared vision device, usually a focal plane array (FPA) infrared camera capable of detecting radiation in the mid (3 to 5 μm) and long (7 to 14 μm) wave infrared bands, denoted as MWIR and LWIR, corresponding to two of the high transmittance infrared windows. Abnormal temperature profiles at the surface of an object are an indication of a potential problem.[10]

In passive thermography, the features of interest are naturally at a higher or lower temperature than the background. Passive thermography has many applications such as surveillance of people on a scene and medical diagnosis (specifically thermology).

In active thermography, an energy source is required to produce a thermal contrast between the feature of interest and the background.[11] The active approach is necessary in many cases given that the inspected parts are usually in equilibrium with the surroundings. Given the super-linearities of the black-body radiation, active thermography can also be used to enhance the resolution of imaging systems beyond their diffraction limit or to achieve super-resolution microscopy.[12]

Advantages

[edit]

Thermography shows a visual picture so temperatures over a large area can be compared.[13][14][15] It is capable of catching moving targets in real time.[13][14][15] It is able to find deterioration, i.e., higher temperature components prior to their failure. It can be used to measure or observe in areas inaccessible or hazardous for other methods. It is a non-destructive test method. It can be used to find defects in shafts, pipes, and other metal or plastic parts.[16] It can be used to detect objects in dark areas. It has some medical application, essentially in physiotherapy.

Limitations and disadvantages

[edit]

There are various cameras cheaper and more expensive. Quality cameras often have a high price range (often US$3,000 or more) due to the expense of the larger pixel array (state of the art 1280 x 1024), while less expensive models (with pixel arrays of 40x40 up to 160x120 pixels) are also available. Fewer pixels reduce the image quality making it more difficult to distinguish proximate targets within the same field of view.

There is also a difference in refresh rate. Some cameras may only have a refreshing value of 5 –15 Hz, other (e.g. FLIR X8500sc[3]) 180 Hz or even more in no full window mode.

Also the lens can be integrated or not.

Many models do not provide the irradiance measurements used to construct the output image; the loss of this information without a correct calibration for emissivity, distance, and ambient temperature and relative humidity entails that the resultant images are inherently incorrect measurements of temperature.[17]

Images can be difficult to interpret accurately when based upon certain objects, specifically objects with erratic temperatures, although this problem is reduced in active thermal imaging.[18]

Thermographic cameras create thermal images based on the radiant heat energy it receives.[19] As radiation levels are influenced by the emissivity and reflection of radiation such as sunlight from the surface being measured this causes errors in the measurements.[20]

  • Most cameras have ±2% accuracy or worse in measurement of temperature and are not as accurate as contact methods.[13][14][15]
  • Methods and instruments are limited to directly detecting surface temperatures.

Applications

[edit]
Kite aerial thermogram revealing features on/under a grassed playing field. Thermal inertia and differential transpiration/evaporation are involved
UAS thermal imagery of a solar panel array in Switzerland
AN/PAS-13 thermal rifle scope mounted on an AR-15 rifle
Thermographic image of a ring-tailed lemur

Images from infrared cameras tend to be monochrome because the cameras generally use an image sensor that does not distinguish different wavelengths of infrared radiation. Color image sensors require a complex construction to differentiate wavelengths, and color has less meaning outside of the normal visible spectrum because the differing wavelengths do not map uniformly into the system of color vision used by humans.

Sometimes these monochromatic images are displayed in pseudo-color, where changes in color are used rather than changes in intensity to display changes in the signal. This technique, called density slicing, is useful because although humans have much greater dynamic range in intensity detection than color overall, the ability to see fine intensity differences in bright areas is fairly limited.

For use in temperature measurement the brightest (warmest) parts of the image are customarily colored white, intermediate temperatures reds and yellows, and the dimmest (coolest) parts black. A scale should be shown next to a false color image to relate colors to temperatures. Their resolution is considerably lower than that of optical cameras, mostly only 160 x 120 or 320 x 240 pixels, although more expensive cameras can achieve a resolution of 1280 x 1024 pixels. Thermographic cameras are much more expensive than their visible-spectrum counterparts, though low-performance add-on thermal cameras for smartphones became available for hundreds of dollars in 2014.[21] Higher-end models are often deemed dual-use military grade equipment, and are export-restricted, particularly if the resolution is 640 x 480 or greater, unless the refresh rate is 9 Hz or less. The export from the USA of thermal cameras is regulated by International Traffic in Arms Regulations. A thermal camera was first built into a smartphone in 2016, into the Cat S60.

In uncooled detectors the temperature differences at the sensor pixels are minute; a 1 °C difference at the scene induces just a 0.03 °C difference at the sensor. The pixel response time is also fairly slow, at the range of tens of milliseconds.

Thermography finds many other uses. For example, firefighters use it to see through smoke, find people, and localize hotspots of fires. With thermal imaging, power line maintenance technicians locate overheating joints and parts, a telltale sign of their failure, to eliminate potential hazards. Where thermal insulation becomes faulty, building construction technicians can see heat leaks to improve the efficiencies of cooling or heating air-conditioning.

Hot hooves indicate a sick cow.

Thermal imaging cameras are also installed in some luxury cars to aid the driver (automotive night vision), the first being the 2000 Cadillac DeVille.

Some physiological activities, particularly responses such as fever, in human beings and other warm-blooded animals can also be monitored with thermographic imaging. Cooled infrared cameras can be found at major astronomy research telescopes, even those that are not infrared telescopes.

Applications include:

Thermal imaging cameras convert the energy in the infrared wavelength into a visible light display. All objects above absolute zero emit thermal infrared energy, so thermal cameras can passively see all objects, regardless of ambient light. However, most thermal cameras only see objects warmer than −50 °C (−58 °F).

The spectrum and amount of thermal radiation depend strongly on an object's surface temperature. This makes it possible for a thermal imaging camera to display an object's temperature. However, other factors also influence the radiation, which limits the accuracy of this technique. For example, the radiation depends not only on the temperature of the object, but is also a function of the emissivity of the object. Also, radiation originates from the surroundings and is reflected in the object, and the radiation from the object and the reflected radiation will also be influenced by the absorption of the atmosphere.

The thermographic camera on a Eurocopter EC135 helicopter of the German Federal Police

Fields in which these techniques are used:

Viewed from space by WISE using a thermal camera, asteroid 2010 AB78 appears redder than the background stars as it emits most of its light at longer infrared wavelengths. In visible light and near-infrared it is very faint and difficult to see.

Standards

[edit]
ASTM International (ASTM)
  • ASTM C1060, Standard Practice for Thermographic Inspection of Insulation Installations in Envelope Cavities of Frame Buildings
  • ASTM C1153, Standard Practice for the Location of Wet Insulation in Roofing Systems Using Infrared Imaging
  • ATSM D4788, Standard Test Method for Detecting Delamination in Bridge Decks Using Infrared Thermography
  • ASTM E1186, Standard Practices for Air Leakage Site Detection in Building Envelopes and Air Barrier Systems
  • ASTM E1934, Standard Guide for Examining Electrical and Mechanical Equipment with Infrared Thermography
International Organization for Standardization (ISO)
  • ISO 6781, Thermal insulation – Qualitative detection of thermal irregularities in building envelopes – Infrared method
  • ISO 18434-1, Condition monitoring and diagnostics of machines – Thermography – Part 1: General procedures
  • ISO 18436-7, Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel – Part 7: Thermography

Biological counterpart

[edit]

Thermography by definition is by means of an instrument (artifact), but some living creatures have natural organs that function as counterparts to bolometers, and thus possess a crude type of thermal imaging capability (thermoception). One of the best known examples is infrared sensing in snakes.

CCD and CMOS thermography

[edit]
Color contours of temperature for a smoldering ember measured with a CMOS camera.

Non-specialized charge-coupled device (CCD) and CMOS sensors have most of their spectral sensitivity in the visible light wavelength range. However, by utilizing the "trailing" area of their spectral sensitivity, namely the part of the infrared spectrum called near-infrared (NIR), and by using off-the-shelf CCTV camera it is possible under certain circumstances to obtain true thermal images of objects with temperatures at about 280 °C (536 °F) and higher.[38]

At temperatures of 600 °C and above, inexpensive cameras with CCD and CMOS sensors have also been used for pyrometry in the visible spectrum. They have been used for soot in flames, burning coal particles, heated materials, SiC filaments, and smoldering embers.[39] This pyrometry has been performed using external filters or only the sensor's Bayer filters. It has been performed using color ratios, grayscales, and/or a hybrid of both.

History

[edit]

Discovery and research of infrared radiation

[edit]

Infrared was discovered in 1800 by Sir William Herschel as a form of radiation beyond red light.[40] These "infrared rays" (infra is the Latin prefix for "below") were used mainly for thermal measurement.[41] There are four basic laws of IR radiation: Kirchhoff's law of thermal radiation, Stefan–Boltzmann law, Planck's law, and Wien's displacement law. The development of detectors was mainly focused on the use of thermometers and bolometers until World War I. A significant step in the development of detectors occurred in 1829, when Leopoldo Nobili, using the Seebeck effect, created the first known thermocouple, fabricating an improved thermometer, a crude thermopile. He described this instrument to Macedonio Melloni. Initially, they jointly developed a greatly improved instrument. Subsequently, Melloni worked alone, creating an instrument in 1833 (a multielement thermopile) that could detect a person 10 metres away.[42] The next significant step in improving detectors was the bolometer, invented in 1880 by Samuel Pierpont Langley.[43] Langley and his assistant Charles Greeley Abbot continued to make improvements in this instrument. By 1901, it could detect radiation from a cow from 400 metres away and was sensitive to differences in temperature of one hundred thousandths (0.00001 C) of a degree Celsius.[44][45] The first commercial thermal imaging camera was sold in 1965 for high voltage power line inspections.

The first advanced application of IR technology in the civil section may have been a device to detect the presence of icebergs and steamships using a mirror and thermopile, patented in 1913.[46] This was soon outdone by the first accurate IR iceberg detector, which did not use thermopiles, patented in 1914 by R.D. Parker.[47] This was followed by G.A. Barker's proposal to use the IR system to detect forest fires in 1934.[48] The technique was not genuinely industrialized until it was used to analyze heating uniformity in hot steel strips in 1935.[49]

First thermographic camera

[edit]

In 1929, Hungarian physicist Kálmán Tihanyi invented the infrared-sensitive (night vision) electronic television camera for anti-aircraft defense in Britain.[50] The first American thermographic camera developed was an infrared line scanner. This was created by the US military and Texas Instruments in 1947[51][failed verification] and took one hour to produce a single image. While several approaches were investigated to improve the speed and accuracy of the technology, one of the most crucial factors dealt with scanning an image, which the AGA company was able to commercialize using a cooled photoconductor.[52]

The first British infrared linescan system was Yellow Duckling of the mid-1950s.[53] This used a continuously rotating mirror and detector, with Y-axis scanning by the motion of the carrier aircraft. Although unsuccessful in its intended application of submarine tracking by wake detection, it was applied to land-based surveillance and became the foundation of military IR linescan.

This work was further developed at the Royal Signals and Radar Establishment in the UK when they discovered that mercury cadmium telluride was a photoconductor that required much less cooling. Honeywell in the United States also developed arrays of detectors that could cool at a lower temperature,[further explanation needed] but they scanned mechanically. This method had several disadvantages which could be overcome using an electronic scanning system. In 1969 Michael Francis Tompsett at English Electric Valve Company in the UK patented a camera that scanned pyro-electronically and which reached a high level of performance after several other breakthroughs during the 1970s.[54] Tompsett also proposed an idea for solid-state thermal-imaging arrays, which eventually led to modern hybridized single-crystal-slice imaging devices.[52]

By using video camera tubes such as vidicons with a pyroelectric material such as triglycine sulfate (TGS) as their targets, a vidicon sensitive over a broad portion of the infrared spectrum[55] is possible. This technology was a precursor to modern microbolometer technology, and mainly used in firefighting thermal cameras.[56]

Smart sensors

[edit]

One of the essential areas of development for security systems was for the ability to intelligently evaluate a signal, as well as warning of a threat's presence. Under the encouragement of the US Strategic Defense Initiative, "smart sensors" began to appear. These are sensors that could integrate sensing, signal extraction, processing, and comprehension.[57] There are two main types of smart sensors. One, similar to what is called a "vision chip" when used in the visible range, allow for preprocessing using smart sensing techniques due to the increase in growth of integrated microcircuitry.[58] The other technology is more oriented to specific use and fulfills its preprocessing goal through its design and structure.[59]

Towards the end of the 1990s, the use of infrared was moving towards civilian use. There was a dramatic lowering of costs for uncooled arrays, which along with the significant increase in developments, led to a dual-use market encompassing both civilian and military uses.[60] These uses include environmental control, building/art analysis, functional medical diagnostics, and car guidance and collision avoidance systems.[61][62][63][64][65][66]

See also

[edit]

References

[edit]
  1. ^ "Breast Cancer Screening: Thermogram No Substitute for Mammogram". fda.gov. US Food and Drug Administration. 27 October 2017. Archived from the original on 23 June 2018. Retrieved 23 June 2018.
  2. ^ "FLIR infrared cameras help detect the spreading of swine flu and other viral diseases". applegate.co.uk. 29 April 2009. Archived from the original on 29 February 2012. Retrieved 18 June 2013.
  3. ^ a b FLIR x8500sc Thermal imaging camera specifications Archived 2019-07-10 at the Wayback Machine. Retrieved on 2019-07-10.
  4. ^ "Infrared Technology". thermalscope.com. Archived from the original on 8 November 2014. Retrieved 31 October 2014.
  5. ^ Hapke B (19 January 2012). Theory of Reflectance and Emittance Spectroscopy. Cambridge University Press. p. 416. ISBN 978-0-521-88349-8.
  6. ^ "Infrared Technology". thermalscope.com. Archived from the original on 8 November 2014. Retrieved 1 November 2014.
  7. ^ "Hot detectors". spie.org.
  8. ^ "DARPA developing personal LWIR cameras to give soldiers heat vision". gizmag.com. 19 April 2013. Archived from the original on 24 September 2015. Retrieved 20 July 2024.
  9. ^ "Thermal detector with preferentially-ordered thermally sensitive element and method - Raytheon Company". freepatentsonline.com. Archived from the original on 2023-11-18. Retrieved 2024-07-20.
  10. ^ Maldague XP, Jones TS, Kaplan H, Marinetti S, Prystay M (2001). "Fundamentals of infrared and thermal testing.". In Maldague K, Moore PO (eds.). Nondestructive Handbook, Infrared and Thermal Testing z÷÷÷÷. Vol. 3 (3rd ed.). Columbus, Ohio: ASNT Press.
  11. ^ Budzier, Helmut; Gerlach, Gerald (2018), Ida, Nathan; Meyendorf, Norbert (eds.), "Active Thermography", Handbook of Advanced Non-Destructive Evaluation, Cham: Springer International Publishing, pp. 1–19, doi:10.1007/978-3-319-30050-4_13-1, ISBN 978-3-319-30050-4, retrieved 2024-11-20
  12. ^ Graciani G, Amblard F (December 2019). "Super-resolution provided by the arbitrarily strong superlinearity of the blackbody radiation". Nature Communications. 10 (1): 5761. Bibcode:2019NatCo..10.5761G. doi:10.1038/s41467-019-13780-4. PMC 6917796. PMID 31848354.
  13. ^ a b c Costello JT, McInerney CD, Bleakley CM, Selfe J, Donnelly AE (2012-02-01). "The use of thermal imaging in assessing skin temperature following cryotherapy: a review" (PDF). Journal of Thermal Biology. 37 (2): 103–110. Bibcode:2012JTBio..37..103C. doi:10.1016/j.jtherbio.2011.11.008. Archived (PDF) from the original on 2024-10-06. Retrieved 2019-12-11.
  14. ^ a b c Bach AJ, Stewart IB, Minett GM, Costello JT (September 2015). "Does the technique employed for skin temperature assessment alter outcomes? A systematic review" (PDF). Physiological Measurement. 36 (9): R27-51. Bibcode:2015PhyM...36R..27B. doi:10.1088/0967-3334/36/9/r27. PMID 26261099. S2CID 23259170.
  15. ^ a b c Bach AJ, Stewart IB, Disher AE, Costello JT (2015-02-06). "A comparison between conductive and infrared devices for measuring mean skin temperature at rest, during exercise in the heat, and recovery". PLOS ONE. 10 (2): e0117907. Bibcode:2015PLoSO..1017907B. doi:10.1371/journal.pone.0117907. PMC 4319934. PMID 25659140.
  16. ^ Using Thermography to Find a Class of Latent Construction Defects. Globalspec.com. Retrieved on 2013-06-18.
  17. ^ F. Colbert, "Looking Under the Hood: Converting Proprietary Image File Formats Created within IR Cameras for Improved Archival Use"[permanent dead link], Professional Thermographers Association
  18. ^ Infrared Temperature Theory and Application Archived 2024-10-06 at the Wayback Machine. Omega.com. Retrieved on 2013-06-18.
  19. ^ "IR scanning handbook" (PDF). Nhatha. NETA. Retrieved 22 June 2019.
  20. ^ Real Time Emissivity Measurement for Infrared Temperature Measurement Archived 2009-09-25 at the Wayback Machine. Pyrometer.com. Retrieved on 2013-06-18.
  21. ^ Thermal camera answers age-old question Archived 2014-10-08 at the Wayback Machine by Fraser Macdonald, 4 October 2014, Hot Stuff
  22. ^ Kylili A, Fokaides PA, Christou P, Kalogirou SA (2014). "Infrared thermography (IRT) applications for building diagnostics: A review". Applied Energy. 134: 531–549. Bibcode:2014ApEn..134..531K. doi:10.1016/j.apenergy.2014.08.005.
  23. ^ Saxena, A; Ng, EYK; Lim, ST (October 2019). "Infrared (IR) thermography as a potential screening modality for carotid artery stenosis". Computers in Biology and Medicine. 113: 103419. doi:10.1016/j.compbiomed.2019.103419. PMID 31493579. S2CID 202003120.
  24. ^ Saxena, Ashish; Raman, Vignesh; Ng, E. Y. K. (2 October 2019). "Study on methods to extract high contrast image in active dynamic thermography". Quantitative InfraRed Thermography Journal. 16 (3–4): 243–259. doi:10.1080/17686733.2019.1586376. hdl:10356/144497. S2CID 141334526.
  25. ^ Saxena, A; Ng, EYK; Lim, ST (May 2020). "Active dynamic thermography to detect the presence of stenosis in the carotid artery". Computers in Biology and Medicine. 120: 103718. doi:10.1016/j.compbiomed.2020.103718. PMID 32250851. S2CID 215408087.
  26. ^ Saxena, Ashish; Ng, E.Y.K.; Raman, Vignesh; Syarifuddin Bin Mohamed Hamli, Muhammad; Moderhak, Mateusz; Kolacz, Szymon; Jankau, Jerzy (December 2019). "Infrared (IR) thermography-based quantitative parameters to predict the risk of post-operative cancerous breast resection flap necrosis". Infrared Physics & Technology. 103: 103063. Bibcode:2019InPhT.10303063S. doi:10.1016/j.infrared.2019.103063. S2CID 209285015.
  27. ^ Soroko M, Morel MC (2016). Equine thermography in practice. Wallingford - Boston: CABI. ISBN 9781780647876. LCCN 2016935227.
  28. ^ Morgan Hughes; Paul Hopwood; Matilda Dolan; Ben Dolan (4 October 2022). "Applications of thermal imaging for bird surveys: examples from the field". Ringing and Migration: 1–4. doi:10.1080/03078698.2022.2123026. ISSN 0307-8698. Wikidata Q114456608.
  29. ^ Gaszczak A, Breckon TP, Han J (2011). "Real-time people and vehicle detection from UAV imagery". In Röning J, Casasent DP, Hall EL (eds.). Intelligent Robots and Computer Vision XXVIII: Algorithms and Techniques. Vol. 7878. pp. 78780B. Bibcode:2011SPIE.7878E..0BG. CiteSeerX 10.1.1.188.4657. doi:10.1117/12.876663. hdl:1826/7589. S2CID 18710932. {{cite book}}: |journal= ignored (help)[permanent dead link]
  30. ^ Pinggera P, Breckon TF, Bischof H (2012). "On Cross-Spectral Stereo Matching using Dense Gradient Features". Proceedings of the British Machine Vision Conference 2012. BMVA Press. pp. 103.1–103.12. doi:10.5244/C.26.103. ISBN 978-1-901725-46-9.
  31. ^ Thermographic images in active volcanoes surveillance system — TIIMNet project Vesuvius and Solfatara INGV Naples Italy Archived 2012-07-10 at archive.today. Ipf.ov.ingv.it. Retrieved on 2013-06-18.
  32. ^ Infrared Building Inspections — Resources for Electrical, Mechanical, Residential and Commercial Infrared/Thermal Inspections Archived 2018-08-06 at the Wayback Machine. Infrared-buildinginspections.com (2008-09-04). Retrieved on 2013-06-18.
  33. ^ "DC-3 Automatic Electronic Seed Counting Machine for Seeds Medical Particles". Gemstone. Archived from the original on 2024-10-06. Retrieved October 30, 2021.
  34. ^ "Thermal imaging highlights Westminster's energy waste". IRT Surveys. 19 February 2013. Archived from the original on 8 October 2016. Retrieved 15 March 2013.
  35. ^ "Thermal Imaging Application Overview". Bullard. Archived from the original on 16 September 2008. Retrieved 15 March 2013.
  36. ^ "NASA Readies James Webb Space Telescope for December Launch". NASA. 8 September 2021. Archived from the original on 6 October 2024. Retrieved 17 October 2021.
  37. ^ Gallardo-Saavedra, Sara; Hernández-Callejo, Luis; Duque-Perez, Oscar (2018-10-01). "Technological review of the instrumentation used in aerial thermographic inspection of photovoltaic plants". Renewable and Sustainable Energy Reviews. 93: 566–579. Bibcode:2018RSERv..93..566G. doi:10.1016/j.rser.2018.05.027. ISSN 1364-0321. S2CID 115195654.
  38. ^ Porev VA, Porev GV (2004). "Experimental determination of the temperature range of a television pyrometer". Journal of Optical Technology. 71 (1): 70–71. Bibcode:2004JOptT..71...62P. doi:10.1364/JOT.71.000062.
  39. ^ Kim, Dennis K.; Sunderland, Peter B. (2019). "Fire Ember Pyrometry Using a Color Camera (2019)". Fire Safety Journal. 106: 88–93. doi:10.1016/j.firesaf.2019.04.006. S2CID 145942969.
  40. ^ Chilton, Alexander (2013-10-07). "The Working Principle and Key Applications of Infrared Sensors". AZoSensors. Archived from the original on 2020-07-11. Retrieved 2020-07-11.
  41. ^ W. Herschel, 1 "Experiments on the refrangibility of the visible rays of the sun", Philosophical Transactions of the Royal Society of London, vol. 90, pp. 284–292, 1800.
  42. ^ Barr, E. S. (1962). The infrared pioneers—II. Macedonio Melloni. Infrared Physics, 2(2), 67-74.
  43. ^ Langley, S. P. (1880). "The bolometer". Proceedings of the American Metrological Society. 2: 184–190. Archived from the original on 2023-04-14. Retrieved 2024-07-20.
  44. ^ Barr, E. S. (1962). The infrared pioneers—III. Samuel Pierpoint Langley. Infrared Physics, 3 195-206.
  45. ^ "Samuel Pierpont Langley". earthobservatory.nasa.gov. 2000-05-03. Archived from the original on 2023-06-01. Retrieved 2021-05-12.
  46. ^ L. Bellingham, "Means for detecting the presence at a distance of icebergs, steamships, and other cool or hot objects," US patent no. 1,158,967.
  47. ^ Parker (R.D.)- Thermic balance or radiometer. U.S. Patent No 1,099,199 Archived 2024-10-06 at the Wayback Machine June 9, 1914
  48. ^ Barker (G.A.) – Apparatus for detecting forest fires. U.S. Patent No 1,958,702 May 22, 1934
  49. ^ Nichols (G.T.) – Temperature measuring. U.S. Patent No 2,008,793 July 23, 1935
  50. ^ Naughton, Russell (10 August 2004). "Kalman Tihanyi (1897–1947)". Monash University. Archived from the original on 24 October 2003. Retrieved 15 March 2013.
  51. ^ "Texas Instruments - 1966 First FLIR units produced". ti.com. Archived from the original on 2024-10-06. Retrieved 2024-07-20.
  52. ^ a b Kruse, Paul W; Skatrud, David Dale (1997). Uncooled infrared imaging arrays and systems. San Diego: Academic Press. ISBN 9780080864440. OCLC 646756485.
  53. ^ Gibson, Chris (2015). Nimrod's Genesis. Hikoki Publications. pp. 25–26. ISBN 978-190210947-3.
  54. ^ "Michael F. Tompsett, TheraManager". uspto.gov. 7 February 2023. Archived from the original on 6 October 2024. Retrieved 20 July 2024.
  55. ^ Goss, A. J.; Nixon, R. D.; Watton, R.; Wreathall, W. M. (1985). "Progress in IR Television Using the Pyroelectric Vidicon". In Mollicone, Richard A.; Spiro, Irving J. (eds.). Infrared Technology X. Vol. 510. p. 154. Bibcode:1985SPIE..510..154G. doi:10.1117/12.945018. S2CID 111164581. {{cite book}}: |journal= ignored (help)
  56. ^ "Heritage TICs EEV P4428 & P4430 Cameras". Archived from the original on 2021-07-23. Retrieved 2024-07-20.
  57. ^ Corsi, C. (1995-07-01). "Smart sensors". Microsystem Technologies. 1 (3): 149–154. Bibcode:1995MiTec...1..149C. doi:10.1007/BF01294808. ISSN 1432-1858. S2CID 86519711.
  58. ^ Moini, Alireza (March 1997). "Vision Chips or Seeing Silicon". The Centre for High-Performance Integrated Technologies and Systems.
  59. ^ National patent no. 47722◦/80.
  60. ^ A. Rogalski, "IR detectors: status trends," Progress in Quantum Electronics, vol. 27, pp. 59–210, 2003.
  61. ^ Corsi, Carlo (2010). "History highlights and future trends of infrared sensors". Journal of Modern Optics. 57 (18): 1663–1686. Bibcode:2010JMOp...57.1663C. doi:10.1080/09500341003693011. S2CID 119918260.
  62. ^ C. Corsi, "Rivelatori IR: stato dell’arte e trends di sviluppo futuro," Atti della Fondazione Giorgio Ronchi, vol. XLVI, no.5, pp. 801–810, 1991.
  63. ^ L. J. Kozlowski and W. F. Kosonocky, "Infrared detector arrays," in Hand-Book of Optics, M. Bass, Ed., chapter 23, Williams, W. L.Wolfe, and McGraw-Hill, 1995.
  64. ^ C. Corsi, "Future trends and advanced development in I.R. detectors," in Proceedings of 2nd Joint Conference IRIS-NATO, London, UK, June 1996.
  65. ^ M. Razeghi, "Current status and future trends of infrared detectors," Opto-Electronics Review, vol. 6, no. 3, pp. 155–194, 1998.
  66. ^ Corsi, Carlo. "Infrared: A Key Technology for Security Systems." Advances in Optical Technologies 2012 (2012): 1-15.
[edit]