Dilution assay
The term dilution assay is generally used to designate a special type of bioassay in which one or more preparations (e.g. a drug) are administered to experimental units at different dose levels inducing a measurable biological response. The dose levels are prepared by dilution in a diluent that is inert in respect of the response. The experimental units can for example be cell-cultures, tissues, organs or living animals. The biological response may be quantal (e.g. positive/negative) or quantitative (e.g. growth). The goal is to relate the response to the dose, usually by interpolation techniques, and in many cases to express the potency/activity of the test preparation(s) relative to a standard of known potency/activity.
Dilution assays can be direct or indirect. In a direct dilution assay the amount of dose needed to produce a specific (fixed) response is measured, so that the dose is a stochastic variable defining the tolerance distribution. Conversely, in an indirect dilution assay the dose levels are administered at fixed dose levels, so that the response is a stochastic variable.
In some assays, there may be strong reasons for believing that all the constituents of the test preparation except one, are without any effect on the studied response of the subjects. An assay of the preparation against a standard preparation of the effective constituent, is then equivalent to an analysis for determining the content of the constituent. This may be described as analytical dilution assay.
Statistical models
[edit]For a mathematical definition of a dilution assay an observation space is defined and a function so that the responses are mapped to the set of real numbers. It is now assumed that a function exists which relates the dose to the response
in which is an error term with expectation 0. is usually assumed to be continuous and monotone. In situations where a standard preparation is included it is furthermore assumed that the test preparation behaves like a dilution (or concentration) of the standard
- , for all
where is the relative potency of . This is the fundamental assumption of similarity of dose-response curves which is necessary for a meaningful and unambiguous definition of the relative potency. In many cases it is convenient to apply a power transformation with or a logarithmic transformation . The latter can be shown to be a limit case of so if is written for the log transformation the above equation can be redefined as
- , for all .
Estimates of are usually restricted to be member of a well-defined parametric family of functions, for example the family of linear functions characterized by an intercept and a slope. Statistical techniques such as optimization by Maximum Likelihood can be used to calculate estimates of the parameters. Of notable importance in this respect is the theory of Generalized Linear Models with which a wide range of dilution assays can be modelled. Estimates of may describe satisfactorily over the range of doses tested, but they do not necessarily have to describe beyond that range. However, this does not mean that dissimilar curves can be restricted to an interval where they happen to be similar.
In practice, itself is rarely of interest. More of interest is an estimate of or an estimate of the dose that induces a specific response. These estimates involve taking ratios of statistically dependent parameter estimates. Fieller's theorem can be used to compute confidence intervals of these ratios.
Some special cases deserve particular mention because of their widespread use: If is linear and this is known as a slope-ratio model. If is linear and this is known as a parallel line model. Another commonly applied model is the probit model where is the cumulative normal distribution function, and follows a binomial distribution.
Example: Microbiological assay of antibiotics
[edit]An antibiotic standard (shown in red) and test preparation (shown in blue) are applied at three dose levels to sensitive microorganisms on a layer of agar in petri dishes. The stronger the dose the larger the zone of inhibition of growth of the microorganisms. The biological response is in this case the zone of inhibition and the diameter of this zone can be used as the measurable response. The doses are transformed to logarithms and the method of least squares is used to fit two parallel lines to the data. The horizontal distance between the two lines (shown in green) serves as an estimate of the potency of the test preparation relative to the standard.
Software
[edit]The major statistical software packages do not cover dilution assays although a statistician should not have difficulties to write suitable scripts or macros to that end. Several special purpose software packages for dilution assays exist.
References
[edit]- Finney, D.J. (1971). Probit Analysis, 3rd Ed. Cambridge University Press, Cambridge. ISBN 0-521-08041-X
- Finney, D.J. (1978). Statistical Method in Biological Assay, 3rd Ed. Griffin, London. ISBN 0-02-844640-2
- Govindarajulu, Z. (2001). Statistical Techniques in Bioassay, 2nd revised and enlarged edition, Karger, New York. ISBN 3-8055-7119-4
External links
[edit]Software for dilution assays: