Jump to content

California bearing ratio

From Wikipedia, the free encyclopedia

The California Bearing Ratio (CBR) is a measure of the strength of the subgrade of a road or other paved area, and of the materials used in its construction.

The ratio is measured using a standardized penetration test first developed by the California Division of Highways for highway engineering.[1] Empirical tests measure the strength of the material and are not a true representation of the resilient modulus.[citation needed]

Definition

[edit]

The CBR is the ratio of the bearing load that penetrates a material to a specific depth compared with the load giving the same penetration into crushed stone. The test measures neither Stiffness Modulus nor Shear Strength directly, but gives a combined measure of both.[2]

Penetration is measured by applying the bearing load on the sample using a standard plunger of diameter 50 mm at the rate of 1.25 mm/min. The CBR is expressed as a percentage of the actual load causing the penetrations of 2.5 mm or 5.0 mm to the standard loads on crushed stone. A load penetration curve is drawn. The load values on standard crushed stones are 1,370 kgf (13.44 kN) and 2,055 kgf (20.15 kN) at 2.5 mm and 5.0 mm penetrations respectively.[citation needed]

The CBR can be mathematically expressed as:

= measured pressure for site soils [N/mm2]
= pressure to achieve equal penetration on standard crushed stone [N/mm2]

Test procedure

[edit]

The CBR test is a penetration test in which a standard piston, with a diameter of 50 mm (1.969 in), is used to penetrate the soil at a standard rate of 1.25 mm/minute.

Although the force increases with the depth of penetration, in most cases, it does not increase as quickly as it does for the standard crushed rock, so the ratio decreases. In some cases, the ratio at 5 mm may be greater than that at 2.5 mm. If this occurs, the ratio at 5 mm should be used. The CBR is a measure of resistance of a material to penetration of a standard plunger under controlled density and moisture conditions. The test procedure should be strictly adhered to if a high degree of reproducibility is desired. The CBR test may be conducted on a remolded or undisturbed specimen in the laboratory. The test is simple and has been extensively investigated for field correlations of flexible pavement thickness requirement.[3][4]

The laboratory CBR apparatus consists of a mould of 150 mm diameter with a base plate and a collar, a loading frame and dial gauges for measuring the penetration values and the expansion on soaking. If a soaked (wet) measurement is desired, the specimen in the mould is soaked in water for four days and the swelling and water absorption values are noted. The surcharge weight is placed on the top of the specimen in the mould and the assembly is placed under the plunger of the loading frame.[5]

Example values

[edit]

CBR values for common soil subgrades can be estimated according to the USC soil types, for example: clay around 2%, sand from 7% (poorly graded) to 10% (well graded), well graded sandy gravel 15%, clayey sand 5-20%, silty gravel 20-60%, gravel from 30-60% poorly-graded to 40-80% if well-graded.[6][7]

References

[edit]
  1. ^ Horonjeff, Robert; Jones, John Hugh (1953). The Design of Flexible and Rigid Pavements. University of California Press. p. 1.
  2. ^ "Interim Advice Note 73/06 Design guidance for road pavement foundations" (PDF). Standards for Highways. Feb 2006. Retrieved June 17, 2022.
  3. ^ Boddie, Francis. "CBR Testing UK". cbrtesting.com. Archived from the original on 9 June 2019. Retrieved 23 May 2019.
  4. ^ Jamal, Haseeb. "CBR Test". AboutCivil.Org. Archived from the original on 23 September 2019. Retrieved 23 September 2019.
  5. ^ California Bearing Ratio Test
  6. ^ "Soil Stiffness and Problem Soils and draw the curve" (PDF). University of Memphis. p. 14.
  7. ^ The SuDS manual (v6 ed.). London: CIRIA. 2015. p. 409. ISBN 978-0-86017-759-3. Archived from the original on 2021-06-14. Retrieved 2021-06-14.