Bloch–Siegert shift

From Wikipedia, the free encyclopedia
The pot lid is rotating around an axis along the surface of the table that is quickly rotating. This results in a secondary rotation which is perpendicular to the table. This is equivalent to the Bloch–Siegert shift and can be seen by watching the motion of the red dot.

The Bloch–Siegert shift is a phenomenon in quantum physics that becomes important for driven two-level systems when the driving gets strong (e.g. atoms driven by a strong laser drive or nuclear spins in NMR, driven by a strong oscillating magnetic field).

When the rotating-wave approximation (RWA) is invoked, the resonance between the driving field and a pseudospin occurs when the field frequency is identical to the spin's transition frequency . The RWA is, however, an approximation. In 1940 Felix Bloch and Arnold Siegert showed that the dropped parts oscillating rapidly can give rise to a shift in the true resonance frequency of the dipoles.

The Bloch–Siegert shift has been used for practical purposes in both NMR and MRI, including power calibration,[1] image encoding,[2][3] and magnetic field mapping.[4]

Rotating wave approximation

[edit]

In RWA, when the perturbation to the two level system is , a linearly polarized field is considered as a superposition of two circularly polarized fields of the same amplitude rotating in opposite directions with frequencies . Then, in the rotating frame(), we can neglect the counter-rotating field and the Rabi frequency is

where is the on-resonance Rabi frequency.

Bloch–Siegert shift

[edit]

Consider the effect due to the counter-rotating field. In the counter-rotating frame (), the effective detuning is and the counter-rotating field adds a driving component perpendicular to the detuning, with equal amplitude . The counter-rotating field effectively dresses the system, where we can define a new quantization axis slightly tilted from the original one, with an effective detuning

Therefore, the resonance frequency () of the system dressed by the counter-rotating field is away from our frame of reference, which is rotating at

and there are two solutions for

and

The shift from the RWA of the first solution is dominant, and the correction to is known as the Bloch–Siegert shift:

The counter-rotating frequency gives rise to a population oscillation at , with amplitude proportional to , and phase that depends on the phase of the driving field.[5] Such Bloch–Siegert oscillation may become relevant in spin flipping operations at high rate. This effect can be suppressed by using an off-resonant Λ transition.[6]

Applications

[edit]

NMR

[edit]

When homonuclear nuclear magnetic resonance decoupling is performed, Bloch–Siegert shifts may become significant due to the strength of the homonuclear decoupling field. Direct measurement of the homonuclear decoupling mean field strength can be achieved by measuring the resulting Bloch–Siegert shift.[7]

MRI

[edit]

The Bloch–Siegert shift is currently being widely investigated a potential encoding mechanism for MRI. The first significant use of the phenomenon in the MR imaging community was to perform mapping of the RF transmit field, by using the imaging system to measure the spatial phase accrual produced by an off-resonant RF pulse.[4] Since then, it has been recognized that Bloch–Siegert shifts can be used in MRI sequences within imaging systems with a transmit field gradient to provide slice selection,[2] phase encoding,[8] and frequency encoding. The motivation for this research is to provide an alternative to conventional gradient encoding, which is currently used in clinical imaging systems but produces undesirable acoustic noise, peripheral nerve stimulation, and spatial design constraints.

AC-Stark shift

[edit]

The AC-Stark shift is a similar shift in the resonance frequency, caused by a non-resonant field of the form perturbing the spin. It can be derived using a similar treatment as above, invoking the RWA on the off-resonant field. The resulting AC-Stark shift is: , with .

References

[edit]
  1. ^ Claridge, Timothy D.W. (2009). Tetrahedron Organic Chemistry Series. Amsterdam, The Netherlands: Elsevier Ltd. p. 90. ISBN 978-0-08-054628-5.
  2. ^ a b Martin, Jonathan B.; et al. (September 2022). "Selective Excitation Localized by the Bloch-Siegert Shift and a B1+ Gradient". Magnetic Resonance in Medicine. 88 (3): 1081–1097. doi:10.1002/mrm.29271. PMC 9246893. PMID 35468232.
  3. ^ Srinivas, Sai Abitha; et al. (August 2024). "Linear Bloch–Siegert phase-encoded low-field MRI: RF coils, pulse sequence, and image reconstruction". NMR in Biomedicine. 37 (12): e5245. doi:10.1002/nbm.5245. PMID 39187938.
  4. ^ a b Sacolick, Laura I.; et al. (May 2010). "B1 Mapping by Bloch-Siegert Shift". Magnetic Resonance in Medicine. 63 (5): 1315–1322. doi:10.1002/mrm.22357. PMC 2933656. PMID 20432302.
  5. ^ Cardoso, George C.; et al. (23 June 2005). "In situ detection of the temporal and initial phase of the second harmonic of a microwave field via incoherent fluorescence". Physical Review A. 71 (6): 063408. arXiv:quant-ph/0410219. Bibcode:2005PhRvA..71f3408C. doi:10.1103/PhysRevA.71.063408.
  6. ^ Pradhan, Prabhakar (28 March 2009). "Suppression of error in qubit rotations due to Bloch–Siegert oscillation via the use of off-resonant Raman excitation". Journal of Physics B: Atomic, Molecular and Optical Physics. 42 (6): 065501. Bibcode:2009JPhB...42f5501P. doi:10.1088/0953-4075/42/6/065501. S2CID 15051122.
  7. ^ Bloch, F.; Siegert, A. (1940). "Magnetic Resonance for Nonrotating Fields". Phys. Rev. 57 (6): 522–527. doi:10.1103/PhysRev.57.522.
  8. ^ Kartӓusch, Ralf; et al. (October 2014). "Spatial phase encoding exploiting the Bloch-Siegert shift effect". MAGMA. 27 (5): 363–371. doi:10.1007/s10334-013-0417-0. PMID 24254040.
  • L. Allen and J. H. Eberly, Optical Resonance and Two-level Atoms, Dover Publications, 1987.