Jump to content

Interrupter

From Wikipedia, the free encyclopedia
(Redirected from Interrupters)
Golding Bird's original sketch of his interrupter circuit.
Description: The prongs at the end of the pivoted arm dip into mercury filled recesses. This completes a circuit which energises a coil around the iron pivot arm and functions as an electromagnet. The magnetic polarity is so arranged that a permanent magnet underneath the arm then repels the pivot arm and causes the circuit to break, but the prongs at the other end of the pivot arm then close an identical circuit at that end and the procedure repeats endlessly. The output of the interrupter is fed to an induction coil which greatly increases the voltage applied to the patient by transformer action.[1]

An interrupter in electrical engineering is a device used to interrupt the flow of a steady direct current for the purpose of converting a steady current into a changing one. Frequently, the interrupter is used in conjunction with an inductor (coil of wire) to produce increased voltages either by a back emf effect or through transformer action. The largest industrial use of the interrupter was in the induction coil, the first transformer, which was used to produce high voltage pulses in scientific experiments and to power arc lamps, spark gap radio transmitters, and the first X-ray tubes, around the turn of the 20th century. Its largest use was the contact breaker or "points" in the distributor of the ignition system of gasoline engines, which served to periodically interrupt the current to the ignition coil producing high voltage pulses which create sparks in the spark plugs. It is still used in this application.

Medical use

[edit]

Bird's interrupter

[edit]

The physician Golding Bird designed his own interrupter circuit for delivering shocks to patients from a voltaic cell through an induction coil. Previously, the interrupter had been a mechanical device requiring the physician to manually turn a cog wheel, or else employ an assistant to do this. Bird wished to free his hands to better apply the electricity to the required part of the patient. His interrupter worked automatically by magnetic induction and achieved a switching rate of around 5 Hz (five times per second).[1] The faster the interrupter switches, the more frequently an electric shock is delivered to the patient and the aim is to make this as high as possible.[2]

Page's interrupter

[edit]

A rather more cumbersome interrupter was constructed by the American Charles Page slightly earlier in 1838 but Bird's work was entirely independent. Although there is little in common between the two interrupter designs, Page takes the credit for being the first to use permanent magnets in an automatic interrupter circuit. Bird's (and Page's) interrupter had the medically disadvantageous feature that current was supplied in opposite directions during the make and break operations, although the current was substantially less during the make operation than the break (current is only supplied at all while the switch is dynamically changing). Treatment often required that current was supplied in one specified direction only.

Letheby's interrupter

[edit]

A modified version of the interrupter was produced by Henry Letheby which could output only the make, or only the break currents by a mechanism consisting of two spoked wheels. Bird also produced a uni-directional interrupter using a mechanism we would now call split-rings. The date of Bird's design is uncertain but may predate Letheby's. Both designs suffered from the disadvantage that automatic operation was lost and the interrupter had to once again be hand-cranked. Nevertheless, this arrangement remained a cheaper option than electromagnetic generators for some time.[1][3]

Other designs

[edit]

Other early interrupters worked by clockwork mechanisms or (non-magnetic) reed switches operated by motion of the patient's limbs. One example of such a device is found in the Pulvermacher chain.[4]

See also

[edit]

References

[edit]
  1. ^ a b c Bird (1838), pp. 18–22
  2. ^ Coley, p.368
    Morus, pp. 250–251
  3. ^ Morus, pp. 250–251
    Bird, Lectures, pp. 119–122
    Letheby, pp. 858–859
  4. ^ Lardner, p.289
    Pulvermacher, p.2

Bibliography

[edit]
  • Bird, Golding "Observations on induced electric currents, with a description of a magnetic contact-breaker", Philosophical Magazine, pp. 18–22, no.71, vol.12, January 1838.
  • Bird, Golding Lectures on Electricity and Galvanism, in their physiological and therapeutical relations, Wilson & Ogilvy, London, 1847.
  • Coley, N. G. "The collateral sciences in the work of Golding Bird (1814–1854)", Medical History, vol.13, iss.4, pp. 363–376, October 1969.
  • Morus, Iwan Rhys Frankenstein's Children: Electricity, Exhibition, and Experiment in Early-nineteenth-century London, Princeton University Press, 1998 ISBN 0-691-05952-7.
  • Lardner, Dionysius Electricity, Magnetism, and Acoustics, London: Spottiswoode & Co. 1856.
  • Letheby, Henry "A description of a new electro-magnetic machine adapted so as to give a succession of shocks in one direction", London Medical Gazette, pp. 858–859, 13 November 1846.
  • Pulvermacher, Isaac Lewis "Improvement in voltaic batteries and apparatus for medical and other purposes", U.S. patent 9,571, issued 1 February 1853.