English: Graph originally published in 3rd International Congress on Energy Efficiency and Renewable Energy Sources Proceedings, 2007 paper: Determining energy savings using utility bills: a winning method for ESCOs
This is a retouched picture, which means that it has been digitally altered from its original version. Modifications: SVG. The original can be viewed here: UtilityBills.gif: .
I, the copyright holder of this work, hereby publish it under the following license:
to share – to copy, distribute and transmit the work
to remix – to adapt the work
Under the following conditions:
attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
https://creativecommons.org/licenses/by/3.0CC BY 3.0 Creative Commons Attribution 3.0 truetrue
Table
Table 1: IPMVP Options
Description
Typical Applications
A
Partially Measured Retrofit Isolation
Savings are determined by partial field measurements of the energy use of the system(s) to which an ECM was applied. Some, but not all, parameters may be stipulated.
Lighting retrofit where pre- and post-retrofit fixture Wattages are measured. Operating hours of the lights are typically agreed upon.
B
Retrofit Isolation
Savings are determined by field measurement of the energy use of the systems to which the ECM was applied.
Variable speed drive on a pump. Electricity use is measured by a kWh meter installed on the electrical supply to the pump motor.
C
Whole Facility
(Utility Bills)
Savings are determined by measuring energy use at the utility meter level. Bills may be corrected for weather.
Several ECMs affecting many systems in a building. Utility Bills are used.
D
Calibrated Simulation
Savings are determined using building simulation. This option is rarely used, and is used primarily when there is no pre-retrofit utility data available.
Multifaceted energy management program affecting many systems in a building but where no base-year data are available.
Original upload log
This image is a derivative work of the following images:
2009-02-04T21:23:15Z Marcelivan 440x553 (37964 Bytes) {{Information |Description={{en|1=Graph originally published in 3rd International Congress on Energy Efficiency and Renewable Energy Sources Proceedings, 2007 paper: DETERMINING ENERGY SAVINGS USING UTILITY BILLS: A WINNING M
{{Information |Description={{en|1=Graph originally published in 3rd International Congress on Energy Efficiency and Renewable Energy Sources Proceedings, 2007 paper: DETERMINING ENERGY SAVINGS USING UTILITY BILLS: A WINNING METHOD FOR ESCOS}} |Source=*[[:
{{Information |Description={{en|1=Graph originally published in 3rd International Congress on Energy Efficiency and Renewable Energy Sources Proceedings, 2007 paper: DETERMINING ENERGY SAVINGS USING UTILITY BILLS: A WINNING METHOD FOR ESCOS}} |Source=*[[: