Jump to content

Mixed oxidant

From Wikipedia, the free encyclopedia
(Redirected from Draft:Mixed oxidant)

A mixed oxidant solution (MOS) is a type of disinfectant that has many uses including disinfecting, sterilizing, and eliminating pathogenic microorganisms in water.[1] An MOS may have advantages such as a higher disinfecting power, stable residual chlorine in water, elimination of biofilm, and safety.[2] The main components of an MOS are chlorine and its derivatives (ClO and HClO), which are produced by electrolysis of sodium chloride.[3] It may also contain high amounts of hydroxy radicals, chlorine dioxide, dissolved ozone, hydrogen peroxide and oxygen from which the name "mixed oxidant" is derived.

Performance

[edit]

Reactions

[edit]

A mixed oxidant solution (MOS) is produced by on-site electrolysis. The concentration of disinfectant output is proportional to the concentration of salt input, voltage, temperature, current, and electrolysis time.[4] An MOS production system contains corrosion-resistant electrodes or dimensionally-stable anodes (DSA) and is made so that different voltages for electrolysis are applied simultaneously to different parts. In this way, different reactions occur at the anode and cathode poles, and therefore, various oxidizing substances are produced.[5]

In this process, the chloride ions at the anode are converted to chlorine gas. After reducing the concentration of chloride ions in the presence of ClO and Cl2 compounds in the solution and applying the required conditions, ClO2 is produced and the final solution is stored.[6]

Half-reaction (V)
2Cl ⇌ Cl2 + 2e

−1.36

0.5Cl2 + H2OHClO + H+ + e

−1.61

Cl + H2O ⇌ HClO + H+ + e

-1.48

Cl + 2OHClO + H2O + 2e

-0.81

HClO + H2O → ClO2+ 3H++ 3e

-1.19

For generating ozone, the conditions for water electrolysis reactions must be provided. In this case, the following half reactions take place (which are given below). Hydrogen gas is produced at the cathode and oxygen gas at the anode. By increasing the voltage, the anode half reaction is changed and ozone is produced.[7]

Half-reaction (V)
2H2O + 2e ⇌ H2 + 2OH

−0.8277

2H2O ⇌ O2 + 4H+ + 4e

−1.229

3H2O ⇌ O3+6H++6e

−1.53

The rate of ozone generation is influenced by the conditions of the electrolysis reactor. Sustained reactions are capable of generating a solution saturated in ozone, though the solubility of ozone depends on the concentration of other ions.[8]

In the next stage, with little change in reaction conditions, hydrogen peroxide is produced. Hydrogen peroxide and ozone are produced by different half reactions, but each of them may occur in practice.[6]

Half-reaction (V)
O2 + H2O ⇌ O3 + 2H+ + 2e

−2.076

O2 + 2OH ⇌ O3 + H2O + 2e

−1.24

3H2O ⇌ O3 + 6H+ + 6e

−1.53

O2 + 2H+ + 2eH2O2

−0.7

2H2O ⇌ H2O2 + 2H+ + 2e

−1.776

HO2 + H+ + e ⇌ H2O2

−1.495

Various conditions, including changes in voltage, current, concentration, pH, temperature, flow, and pressure will change the standard reduction potential, and as a result, the rate of various reactions. However, the extent of the electrodes in the reactor, creating multiple layers of electrolyte and unequal conditions on the electrodes surfaces, will cause major changes in the standard modes of the half reactions.[7]

Production Cell

[edit]
Operation principle of NaCl electrolysis cell

The basis of the mixed oxidant production cell is electrolysis of a water solution of sodium chloride. For producing a mixed oxidants solution, different types of electrolysis cells such as a membrane cell or a standard contact cell (both unipolar and bipolar) are used.[9]

Membrane cell

[edit]

This cell consists of anode and cathode electrodes with an ion exchange membrane between them. This membrane allows cations pass through it and leads them to the cathode.[10] This cell has two inputs and two outputs for water. One pair of input and output is located at the cathode side and the other pair is located at the anode side.[11]

Certain cells feature various types of membranes. Some use ion exchange membranes capable of transporting cations and anions across sides. In these cells, a brine solution is introduced from one side, while water is fed from the opposite side.[12]

The half reaction in the cathode chamber is as follows:

2NaCl + 2H2O + 2e→ 2NaOH + 2Cl+ H2

On the anode side, part of the chloride ions are oxidized and dissolved in the passing water in the forms of Cl2, HOCl and small amounts of ClO2 due to the electrolysis of water. Small amounts of ozone and oxygen gas are produced at the anode side. The main half reaction at the anode side is:

2Cl→ 2e+ Cl2
Cl+ H2O → HClO + H++ 2e

When water flows through the anode chamber, it dissolves chlorine and its compounds. By adding the necessary quantity of this mixture to water, it can be purified. The solution exiting the anode chamber in membrane reactors is acidic, with a pH of about 2-3. Fixed titanium electrodes, which are resistant to corrosion at the anode, are suitable for this kind of electrolysis cell.[13]

Membraneless cell

[edit]
Electrode arrangements in salt electrolysis reactors

The structure of the cell without a membrane is similar to a membrane cell, with the exception that it has one brine solution input and one output for the products. In this case, the anode and cathode products are mixed and go to the cell output. Since the pH of the produced solution is around 8-9, using this solution for disinfection may be unsuitable for base-sensitive applications. Acidic solution is added to reduce pH in these situations. This type of cell can be unipolar or bipolar, as described below.[14]

Types of cell connections
[edit]

Electrolysis cells with more than one anode and cathode pair have two types of arrangement: unipolar and bipolar.

Unipolar arrangement: Cells are arranged in parallel and therefore have the same potential difference between the anode-cathode pair. The total current flow is equal to the sum of each pair's current and the voltage is equal to one pair's voltage. In this case, the whole system voltage is low and its current is high.[14]

An example of a bipolar arrangement. Half of each electrode plate on both sides is an anode; the other half is the cathode

Bipolar arrangement: Cells are connected in series.[14] Bipolar ordering has multiple configurations. In one case, central electrodes on one side act as the anode and on the other side act as the cathode. In other cases, half of the electrode plate on both sides is the anode and the other half is the cathode.

Comparisons

[edit]

Advantages of Mixed oxidant solution compared to other disinfecting methods

[edit]

Application of mixed-oxidant solution for disinfecting water has several advantages compared to other methods, such as sodium hypochlorite bleach and calcium hypochlorite. The disinfecting effect of applying mixed oxidant is more efficacious and has fewer safety concerns than other methods, such as chlorination and ozonation. It is generally regarded as safer and with fewer risks. A summary of the comparison between the disinfection methods is provided in the table below.[15]

Comparing methods of water disinfection[15]
Mixed oxidant Bleach produced locally UV Ozone Chlorine dioxide Chloramine Calcium hypochlorite Bleach Chlorine gas
Effective Disinfection yes yes yes yes yes yes yes yes yes
safety yes yes yes no no no no no no
Residual chlorine yes yes no no no yes yes yes yes
Less trihalomethanes production yes no yes yes yes yes no no no
Less chlorite and bromate production yes yes yes yes no yes yes yes yes
Biofilm removal yes no no no yes no no no no
Algae removal yes no no yes yes no no no no
Virus removal yes no no yes no no no no no
Remove parasite eggs yes no no no no no no no no
Usage in the pretreatment yes no no yes yes yes no no no
Removing taste and odor yes no no yes no no no no yes
Easy maintenance yes yes no no no yes no no yes

In the next table, the effectiveness of mixed oxidant and bleach in terms of deactivating bacteria and viruses has been compared. In many cases a mixed oxidant is more effective against pathogens either by inactivating more pathogens, requiring less contact time, or less product than bleach.[16] An MOS is also effective against more bacteria and viruses than bleach.[16]

Comparison of Mixed oxidant and Bleach in terms of deactivating bacteria and viruses[16]
Microorganisms Injection rate
(mg/L)
Contact time
(min)
Inactivation
(log)
Differentiating
Parameter
Mixed oxidant Bleach Mixed oxidant Bleach Mixed oxidant Bleach
Bacteria
Vibrio cholerae 2 2 1.8 4.0 4 time
Escherichia coli 2 2 3.8 5.0 4 time
Pseudomonas aeruginosa 2 2 10 10 >4.8 2.2 Efficacy
Legionella pneumophila 2 2 10 10 5 4.7 Efficacy
Staphylococcus aureus 2 2 60 60 1.6 0.8 Efficacy
4 4 60 60 3.7 2.3
Listeria monocytogenes 2 2 60 60 2 0.8
4 4 60 60 3.7 1.2
Bacteria spores
Bacillus stearothermophilus 2 2 30 30 >5 2.5 Efficacy
Clostridium perfringens spore 2 2 13 18 2 time
Bacillus globigii spores

Bacillus anthracis (Sterne) spores

2.5 2.5 15 15 3.6 2.4 Efficacy
Viruses
MS2 Coliphage 2 2 70 168 4 time
Vaccine (Smallpox surrogate) 5 ~70 20 10 4 3

Time, concentration, efficacy

Poliovirus vaccine strain 1 >4 NA 30 NA >5.5 NA
Rotavirus SA-11 >4 NA 30 NA >5.5 NA
Protozoa oocysts
Giardia lamblia >4 NA 30 NA 4 NA
Cryptosporidium parvum 5 5 240 1440 3 >none Time and efficacy
Cryptosporidium parvum oocysts 25 25 240 240 >1 0.25 Efficacy, qRT-PCR and Tissue culture of infectivity.

Comparison of the membrane cell and membraneless cell

[edit]

A mixed oxidant production cell generally works regardless of a membrane. Each of these structures has advantages and disadvantages that should be considered. The membraneless cell output contains hydroxide ions which increase the pH; therefore it affects the composition of the output products. To keep the pH in the neutral range, hydrochloric acid or sulfuric acid must be added to the disinfected water. In this kind of cell, the main product is sodium hypochlorite. On the other hand, in cells with 1 membrane, the anode output (anolyte) is acidic and the cathode output (catholyte) is basic. The anolyte (acidic solution) contains more than four types of oxidants, which can make disinfecting more effective. The output components of these two different cells are compared in the table below.[14]

Comparing output compounds of the membrane cell and the membraneless cell
Oxidizing substance Units Membrane cell Membraneless cell
pH=2–3 pH=8
ozone ppm 20 -
Chlorine dioxide ppm 26 -
Hypochlorous acid ppm 1800 -
Sodium hypochlorite ppm - 1400
Hydrogen Peroxide ppm 40 0
Oxygen ppm 11 5
ORP mV 1140 966

At pH higher than 5, most of the hypochlorous acid turns into hypochlorite ions, which is a weaker oxidant compared to hypochlorous acid. Moreover, in a membrane cell, other powerful oxidants such as ozone, chlorine dioxide and hydrogen peroxide can be produced, which are effective for killing bacteria and omitting[clarification needed] biofilms in water distribution systems and containers.

Comparing membraneless cell and membrane cell
Property Units Bipolar cell without Membrane Membrane cell
Salt intake Grams per grams of Chlorine 5 5
Electricity consumption Watt per grams of Mixed oxidant 7 7
Acid consumption Hydrochloric acid Citric acid
Water consumption Liter per grams of Mixed oxidant 1 2
Maximum concentration of Mixed oxidants Grams per liter 1.6 1.8
Chlorine smell yes yes
Solution pH 8–9 2.5–3

Today, membrane cell systems are some of the most promising and fast-developing techniques for producing Chloralkali (see chloralkali process) and it will undoubtedly replace other techniques. Since 1987, practically all new chloralkali plants worldwide apply the membrane system. However, due to their long lifetime and high replacement costs, the existing mercury and diaphragm cells are only very slowly being replaced with membrane cells.[14]

Applications

[edit]

Mixed oxidant solutions for water treatment may improve safety, lower general corrosion rates, increase performance, and save money. MOS may be more effective than bleach and can be used for a variety of applications. Some of these applications are cited below.

Cooling water treatment: An MOS for industrial cooling water treatment and disinfection improves safety and thermal efficiency, lowers general corrosion rates, increases performance, and saves money, resulting in a reduction of downtime, maintenance, and expense. Additionally, it can improve workplace safety by eliminating the handling and storage of hazardous chemicals while maintaining steady microbiological control.[17]

Cooling tower water treatment: An MOS improves cooling tower efficiency, safety, and cost compared to conventional biocide treatment methods for legionella prevention, biofilm removal, and inactivation of other performance-inhibiting waterborne organisms.[18]

Industrial process water and wastewater treatment: As the lowest cost supplier of chlorine for disinfection and oxidation of process water and wastewater prior to discharge, an MOS is used in industrial wastewater treatment. MOS chemistry is more effective at biofilm control. Biochemical and Chemical oxygen demand removal, breakpoint chlorination of ammonia and hydrogen sulfide removal.[19]

Municipal wastewater: As one of the world's most precious natural resources, the reuse of water is becoming increasingly important. MOS is both the most cost-effective solution and the preferred technology for disinfection and oxidation of wastewater for reuse or reintroduction into the environment eliminating many of the negative problems associated with traditional chlorine disinfection.[19]

Drinking water & beverage facilities: An MOS is a proven disinfectant for improving the quality and safety of drinking water with significant economic savings. For providing clean, safe drinking water ranges from rural communities to large cities. Also providing clean, safe water at food and beverage facilities. It is ideally suited for carbonated soft drinks bottling, brewing, dairy farms and dairy and food processing applications.[20]

Aquatics and pools: An alternative to chlorine for pool cleaning is an MOS. It can reduce skin and eye irritation, and skin redness and dryness often associated with chlorine. An MOS can also reduce maintenance time and costs compared to chlorine as the need for "shocking" and draining the pool is minimized or unnecessary.[21]

Farm applications: There are many disinfecting needs an MOS is utilized for in farm application such as livestock watering, drinking water disinfection, dairy, milking operations, pre- and post-teat dip, CIP sanitizer, poultry cooling & humidification pad treatment, irrigation & drip line cleaning, and iron and manganese removal from the water supply.[19]

Crude oil & gas water management: Enhanced oil recovery almost always involves some kind of water treatment processes. Water treatment technology in the crude oil and gas industry includes disinfection treatment for produced water, frac-water, disposal well sites, enhanced oil recovery, and hydrogen sulfide removal.[22]

References

[edit]
  1. ^ T. Sasahara, M. Aoki, T. Sekiguchi, A. Takahashi, Y. Satoh, H Kitasato, M. Inoue, Effect of the mixed-oxidant solution on infectivity of Cryptosporidium parvum oocysts in a neonatal mouse model, Europe PMC,2003
  2. ^ L V Venczel, M Arrowood, M Hurd and M D Sobsey, Inactivation of Cryptosporidium parvum oocysts and Clostridium perfringens spores by a mixed-oxidant disinfectant and by free chlorine, Appl. Environ. Microbiol. 1997
  3. ^ W.L. Bradford, The Differences between On-Site Generated Mixed-Oxidant Solution and Sodium Hypochlorite, MIOX Master Features Summary, 2011
  4. ^ S.Y. Hsu "Effects of water flow rate, salt concentration and water temperature on efficiency of an electrolyzed oxidizing water generator" Journal of Food Engineering 60, 469–473, 2003
  5. ^ G. C. White, Handbook of chlorination and alternative disinfectants, New York, 4th Edition, 1999.
  6. ^ a b H.S. Weinberg, Rodriguez-Mozaz, and A. Sykes, "Characterization of the Chemical Constituents of Mixed Oxidant Disinfection", Final Project Report, presented to MIOX Corporation by the University of North Carolina, Department of Environmental Sciences and Engineering, Chapel Hill, NC, 23 July 2008.
  7. ^ a b Gordon, G.L., 1998, "Electrochemical Mixed Oxidant Treatment: Chemical Detail of Electrolyzed Salt Brine Technology", prepared for the U.S. Environmental Protection National Risk Management Laboratory, Cincinnati, OH, May 1998.
  8. ^ Roth, John A.; Sullivan, Daniel E. (May 1981). "Solubility of ozone in water". Industrial & Engineering Chemistry Fundamentals. 20 (2): 137–140. doi:10.1021/i100002a004. ISSN 0196-4313.
  9. ^ 47. V.M. Linkov, (2002) Electro-membrane reactors for desalination and disinfection of aqueous solutions. WRC Report No. 964/1/02, University of the Western Cape, Bellville, SA.
  10. ^ Y. Tanaka Ion exchange membranes fundamentals and applications, Membrane science and technology series,12
  11. ^ A. Catarina B. V. Dias "Chlor-Alkali Membrane Cell Process", Doctoral dissertation, University of Porto
  12. ^ E.T. Igunnu and G. Z. Chen "Produced water treatment technologies", international Journal of Low-Carbon Technologies Advance Access, 2012.
  13. ^ M. Siguba "The development of appropriate brine electrolysers for disinfection of rural water supplies", master's thesis, 2005
  14. ^ a b c d e Integrated Pollution Prevention and Control (IPPC)-Reference Document on Best Available Techniques in the Chlor-Alkali Manufacturing industry, 2001
  15. ^ a b National drinking water clearinghouse fact sheet
  16. ^ a b c http://www.howelllabs.com/wp-content/uploads/2013/09/Microbial_MOS_VS_HYPO_Comparison_Table_100413.pdf [bare URL PDF]
  17. ^ A. Boal, Alternative to bromine improves cooling water microbial control and overall treatment, Cooling Technology Institute Annual conference,2015
  18. ^ W. L. Bradford, Mixed oxidant replaces "cocktail" of chemicals in power plant cooling tower water system, Industrial waterworld, 2011
  19. ^ a b c M.D. Sobsey, M.J. Casteel, H. Chung, G. Lovelace, O.D. Simmons and J.S Meschke, Innovative technologies for waste water disinfection and pathogen detection, Proceedings of Disinfection, 1998
  20. ^ C. Crayton, B. Warwood A. Camper, Validation of Mixed-Oxidants For the Disinfection and Removal of Biofilms From Distribution Systems, 1997
  21. ^ W. L. Bradford, Mechanisms for Lack of Swimmer's Complaints in the Presence of a Persistent Combined Chlorine Measurement, 2005
  22. ^ "Home". miox.com.